Question # 1



A Media and Entertainment company is considering changing from 2K resolution to 4K
resolution. They will continue to use the DNxHD 220 codec.
Assuming everything else stays the same, how will this change affect storage?

A.

Storage will be half as large

B.

Storage requirements will not change

C.

Storage will be twice as large

D.

Storage will be four times as large




B.
  

Storage requirements will not change







Question # 2



When using an N+2:1 protection policy on a 7-node Isilon cluster, how much capacity will be used to store a 510 KiB file?

A.

638 KiB

B.

640 KiB

C.

766 KiB

D.

768 KiB




A.
  

638 KiB







Question # 3



Your customer uses an existing Isilon cluster consisting of five NL-Series nodes to source
broadcast media files for playback and streaming.The customer reports that the playback
pauses and stutters regularly. It has been confirmed that there are no network or playback
system issues.
Which of the choices listed is the appropriate choice to address the playback issues?

A.

Add three or more S-Series Nodes

B.

Upgrade OneFS to the latest version

C.

Enable SmartConnect Advanced

D.

Enable Level 2 Caching




A.
  

Add three or more S-Series Nodes







Question # 4



Which balancing option is provided by SmartConnect Basic?

A.

Round-Robin

B.

Throughput

C.

CPU usage

D.

Connection count




A.
  

Round-Robin



Reference: http://doc.isilon.com/onefs/8.1.1/help/en-us/ifs_c_smartconnect_module.html





Question # 5



A customer has an SMB file directory with 375 TB of data on the primary cluster with a
protection level of N+ 3:1. They want to replicate this directory to the secondary cluster.
The customer would like information about the possibility of setting protection levels on the
target cluster.
What information can be provided to the customer about the protection level for the target
directory?

A.

Configured separately on the target cluster and does not need to match the source

B.

Configured separately on the target cluster and must match the source

C.

Controlled by SyncIQ and cannot be altered

D.

Controlled by SyncIQ and can be altered by the CLI




A.
  

Configured separately on the target cluster and does not need to match the source







Question # 6



A company has purchased an Isilon cluster. The storage administrator knows they will have
a large number of clients with similar workloads connecting to the cluster through NFS, and
connections will be maintained for a long time. Which two connection balancing policies
should be recommended for initial use? (Choose two.)

A.

Round Robin and Connection Count

B.

CPU Utilization and Network Throughput

C.

Round Robin and CPU Utilization

D.

Connection Count and Network Throughput




A.
  

Round Robin and Connection Count




B.
  

CPU Utilization and Network Throughput







Question # 7



You are designing a new Isilon system to store mobile device video clips. The files average
800MB in size and the application team tells you to plan for up to 15,000 new files per day.
The product manager for this new service wants enough capacity for the first year and
reminds you that response time for storing and retrieving the files is important for customer
satisfaction.
The files will be accessed frequently for the first 48 hours after creation, and then very
infrequently after seven days. You plan to use N+2:1 protection, and will configure a
SmartPools policy to move inactive files to an archive tier within the cluster.
Which configuration best fits the project requirements?

A.

4 x X200 nodes with SSD; 36 x NL400 nodes with 4TB drives

B.

38 x X400 nodes with 4TB drives and SSD

C.

4 x S200 nodes with SSD; 45 x NL400 nodes with 3TB drives

D.

4 x X400 nodes with 1TB drives; 36 x NL400 nodes with 4TB drives




A.
  

4 x X200 nodes with SSD; 36 x NL400 nodes with 4TB drives







Question # 8



Your customer's initial use case was Home Directories. They implemented the cluster with
four 1Gbps ports and LACP. They are planning to expand their cluster to support their core
file services. They plan to upgrade their network infrastructure to 10 GbE to facilitate this.
What are two design impacts this change will have?

A.

Maximum performance is obtained by only using a single 10GbE interface per
node.LACP and multiple links may be used to increase redundancy, but will not provide
more overall performance to the system

B.

LACP and multiple links may be used to increase redundancy, but will not provide more
overall performance to the system.FCoE should be considered for the External Network
Ports on the nodes.

C.

Dual 10GbE ports on each node will enable throughput of 20Gbps.Only connect half of
the nodes to the network.

D.

Maximum performance is obtained by only using a single 10GbE interface per
node.Isilon can support up to 400MB/s per node




A.
  

Maximum performance is obtained by only using a single 10GbE interface per
node.LACP and multiple links may be used to increase redundancy, but will not provide
more overall performance to the system







Question # 9



An Isilon customer created a scheduled SyncIQ policy to replicate data from an Enterprisemode
SmartLock directory. The source cluster is now unusable and the target cluster does
not automatically allow writes to the data in the replicated SmartLock directory.
What is the reason why the target cluster did not automatically allow writes of the data?

A.

SyncIQ Automated failover is not supported for SmartLock directories; however, manual
failover is allowed.

B.

Automated failover and manual failover are not allowed on SmartLock directories on the target cluster.

C.

A SyncIQ job was running while the source cluster became unusable, thereby removing all data on the target directory.

D.

SnapshotIQ was not licensed on the target cluster; the snapshot of the directory is not available for use by SyncIQ.




A.
  

SyncIQ Automated failover is not supported for SmartLock directories; however, manual
failover is allowed.







Question # 10



Which types of reports are available from InsightIQ?

A.

Auditing and file system

B.

Auditing and security

C.

Performance and file system

D.

Performance and security




C.
  

Performance and file system



Reference: https://www.storagenetworks.com/documents/emc/emc-isilon-insightiq-ug.pdf




Get 344 Isilon Solutions and Design Specialist Exam for Technology Architects questions Access in less then $0.15 per day.

Total Questions Answers: 344
Last Updated: 11-Oct-2024
Available with 1, 3, 6 and 12 Months Free Updates Plans
PDF/ Day: $0.15

Test Engine/ Day: $0.18

PDF + Engine/ Day: $0.20


EMC E20-555 Dumps - Latest Questions


Exam Code: E20-555
Exam Name: Isilon Solutions and Design Specialist Exam for Technology Architects

  • 90 Days Free Updates
  • EMC Experts Verified Answers
  • Printable PDF File Format
  • E20-555 Exam Passing Assurance

Get 100% Real E20-555 Exam Dumps With Verified Answers As Seen in the Real Exam. Isilon Solutions and Design Specialist Exam for Technology Architects Exam Questions are Updated Frequently and Reviewed by Industry TOP Experts for Passing EMC Certification Exam Quickly and Hassle Free.

EMC E20-555 Exam Questions


Struggling with Isilon Solutions and Design Specialist Exam for Technology Architects prep? Get the edge you need!

Our carefully crafted E20-555 dumps give you the confidence to ace the exam. We offer:

  • Up-to-date EMC Certification practice questions: Stay current with the latest exam content.
  • PDF and test engine formats: Choose the study tools that work best for you.
  • Realistic EMC E20-555 practice exams: Simulate the real exam experience and boost your readiness.
Pass your EMC Certification exam with ease. Try our study materials today!


Ace your EMC Certification exam with confidence!



We provide top-quality E20-555 exam prep materials that are:
  • Accurate and up-to-date: Reflect the latest EMC exam changes and ensure you are studying the right content. 
  • Comprehensive: Cover all exam topics so you do not need to rely on multiple sources. 
  • Convenient formats: Choose between PDF files and online Isilon Solutions and Design Specialist Exam for Technology Architects practice tests for easy studying on any device.
Do not waste time on unreliable E20-555 practice exams. Choose our proven EMC Certification study materials and pass with flying colors.

Try Dumps4free Isilon Solutions and Design Specialist Exam for Technology Architects Exam 2024 PDFs today!

  • Assurance

    Isilon Solutions and Design Specialist Exam for Technology Architects practice exam has been updated to reflect the most recent questions from the EMC E20-555 Exam.

  • Demo

    Try before you buy! Get a free demo of our EMC Certification exam dumps and see the quality for yourself. Need help? Chat with our support team.

  • Validity

    Our EMC E20-555 PDF contains expert-verified questions and answers, ensuring you're studying the most accurate and relevant material.

  • Success

    Achieve E20-555 success! Our Isilon Solutions and Design Specialist Exam for Technology Architects exam questions give you the preparation edge.

If you have any question then contact our customer support at live chat or email us at support@dumps4free.com.