Discount Offer
Go Back on NCP-MCI-6.10 Exam
Available in 1, 3, 6 and 12 Months Free Updates Plans
PDF: $15 $60

Test Engine: $20 $80

PDF + Engine: $25 $99



Pass exam with Dumps4free or we will provide you with three additional months of access for FREE.

NCP-MCI-6.10 Practice Test

Whether you're a beginner or brushing up on skills, our NCP-MCI-6.10 practice exam is your key to success. Our comprehensive question bank covers all key topics, ensuring you’re fully prepared.


Page 5 out of 16 Pages

When expanding acluster, what is required toautomatically discover new nodes?


A. New nodes must have the same hypervisor version.


B. IPv6 multicast must be allowed on physical switches.


C. New nodes must have the same AOS version.


D. IPv4 multicast must be allowed on physical switches.





D.
  IPv4 multicast must be allowed on physical switches.

After upgradingPrism Central from PC2022.1 to PC2024.1, an administrator isunable to log inwith their IAM domain account.
What is the first troubleshooting step the administrator should take?


A. Ping the Domain Controller from the CVM.


B. Ensure port 9441 is open in the firewall.


C. Validate the trusted signing certificate of the organization.


D. Log in with a local admin account.





D.
  Log in with a local admin account.

A security team asks an administrator toset up port mirroringof aspecific source VMto atarget VM.
What must the administrator ensure for this configuration to be possible?


A. Source VM and Target VM are on the same VLAN.


B. Source VM and Target VM are on the same host.


C. Source VM and Target VM are on the same subnet.


D. Source VM and Target VM are on the same VPC.





B.
  Source VM and Target VM are on the same host.

An administrator is responsible forresource planningand needs to plan forresiliencyof a10-node RF3 cluster . The cluster has100TB of storage.
How should the administrator plan for capacity in the event of future failures?


A. Set Reserve Storage Capacity (%) to 20.


B. Set Reserve Capacity for Failure to None.


C. Set Reserve Capacity for Failure to Auto Detect.


D. Set Reserve Memory Capacity (%) to 20.





C.
  Set Reserve Capacity for Failure to Auto Detect.

An administrator isprotecting an application and its datastored onVolume GroupsusingProtection Domains.
Duringfailover tests, allapplication VMs restore successfully, but theapplication data is completely missing.
How can the Protection Domain configuration be adjusted to avoid this issue in the future? (Choose two.)


A. Select the "Auto protect related entities" checkbox.


B. Manually add Volume Groups to Protected Entities.


C. Place Volume Groups in a separate Protection Domain.


D. Use application-consistent snapshots.





A.
  Select the "Auto protect related entities" checkbox.

B.
  Manually add Volume Groups to Protected Entities.


Page 5 out of 16 Pages
Previous