Go Back on HPE6-A47 Exam
Available in 1, 3, 6 and 12 Months Free Updates Plans
PDF: $15 $60

Test Engine: $20 $80

PDF + Engine: $25 $99

HPE6-A47 Practice Test


Page 1 out of 13 Pages

A financial institution has an Aruba wireless system. Each floor is 19 meters by 23 meters
(200 feet by 250 feet) and has 20 APs. The organization now requires dedicated Air
Monitors (AMs). About how many AMs should the architect recommend per floor?


A.

about 1 or 2 per floor


B.

about 3 to 5 per floor


C.

about 10 to 12 per floor


D.

about 16 to 20 per floor





A.
  

about 1 or 2 per floor



Refer to the exhibit.

Exhibit 1 shows the logical plan, and Exhibit 2 shows the BOM created with IRIS. An
architect plans to propose two 5406Rzl switches as a VSF fabric for a campus network
core. Which issue with the plan should the architect correct?


A.

Add two QSPF+ MP0 SR4 transceivers.


B.

Change the v2 modules to v3 modules.


C.

Add stacking modules and cables.


D.

Change the power supply type.





B.
  

Change the v2 modules to v3 modules.



An architect plans where to deploy new Aruba 320 Series APs at a customer site. The
architect plans for the APs to be installed on the ceiling where power is inaccessible. The
Ethernet cable run to these locations is CAT6, and the customer wants to support at least 1
GbE connectivity. The architect plans to connect each AP with one Ethernet port to a
switch in a nearby wiring closet.
Which feature does the switch need to support for this deployment?


A.

PoE+


B.

LACP


C.

Port channel


D.

Smart Rate





A.
  

PoE+



A customer requires APs that meet these minimal criteria:
1. Support for MU-MIMO
2. Support for up to four spatial streams, both when MU-MIMO is used and when it is not
used
3. Support for transmissions to up to three MU-MIMO clients at the same time
The architect finds these specifications for the two models under consideration:
AP-335 = 4x4:4:4:4:3
AP-325 = 4x4:4:4:3:3
What should the architect determine from these specifications?


A.

The AP 335 and the AP 325 do not meet the customer requirements, so consider a
different model.


B.

The AP 325 meets the customer requirements, but the AP 335 does not.


C.

Either the AP 335 or the AP 325 meet the customer requirements.


D.

The AP 335 meets the customer requirements, but the AP 325 does not.





C.
  

Either the AP 335 or the AP 325 meet the customer requirements.



Refer to the exhibit.

An architect needs to plan a network solution for a new office building with four floors. Each
floor has two wiring closets with the equipment shown in the exhibit. The switches will
connect to employee desktops, a few campus APs controlled by MCs, and printers. The
switches do not implement tunneled node.
What is a best practice design for the VLANs and subnets for the wired devices?


A.

one VLAN per closet and a /24 subnet for each VLAN


B.

one VLAN per closet and a /25 subnet for each VLAN


C.

one VLAN for the entire building and a /23 subnet


D.

one VLAN per floor and a /24 subnet for each VLAN





B.
  

one VLAN per closet and a /25 subnet for each VLAN




Page 1 out of 13 Pages