Which statement describes monitoring Fibre Channel traffic on a Cisco UCS 6332 Fabric Interconnect?
A.
Fibre Channel traffic is monitored only on one vHBA per server.
B.
The destination port for monitoring must be an unassigned Fibre Channel port.
C.
The monitoring of Fibre Channel traffic is limited to the default VSAN.
D.
Fibre Channel traffic is capable to be monitored as it is encapsulated as FCoE.
Fibre Channel traffic is capable to be monitored as it is encapsulated as FCoE.
Which statement about monitoring Fibre Channel traffic on a Cisco UCS 6332 Fabric Interconnect is true?
A.
The monitoring of Fibre Channel traffic is limited to the default VSAN.
B.
Fibre Channel traffic can be monitored only on one vHBA per server.
C.
The destination port for monitoring must be an unassigned Fibre Channel port.
D.
ibre Channel traffic can be monitored as it is encapsulated as FCoE.
Fibre Channel traffic can be monitored only on one vHBA per server.
A Cisco MDS 9000 series storage Switch has reloaded unexpectedly. Where does the engineer look for the latest core dump file?
A.
/mnt/core
B.
/mnt/pss
C.
/mnt/logs
D.
/mnt/recovery
/mnt/pss
What occurs when running the command install deactivate <filename> while a software maintenance upgrade
A.
The current set of packages is committed.
B.
The package is removed from the switch.
C.
The package features for the line card are disabled.
D.
The current upgrade stops.
The package features for the line card are disabled.
Which configuration generates a syslog message when CPU utilization is higher than 60%?
A.
event manager applet HIGH-CPU
event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op gt 60 poll-interval 5 action 1.0 syslog priority notifications msg "cpu high"
B.
event manager applet HIGH-CPU
event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op lt 60 poll-interval 5 action 1.0 syslog priority notifications msg "cpu high"
C.
event manager applet HIGH-CPU
event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type next entry-op gt 60 poll-interval 5 action 1.0 syslog priority notifications msg "cpu high"
D.
event manager applet HIGH-CPU
event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type next entry-op lt 60 poll-interval 5 action 1.0 syslog priority notifications msg "cpu high"
event manager applet HIGH-CPU
event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op gt 60 poll-interval 5 action 1.0 syslog priority notifications msg "cpu high"
Page 10 out of 41 Pages |
Previous |