Discount Offer
Go Back on 2V0-13.24 Exam
Available in 1, 3, 6 and 12 Months Free Updates Plans
PDF: $15 $60

Test Engine: $20 $80

PDF + Engine: $25 $99



Pass exam with Dumps4free or we will provide you with three additional months of access for FREE.

2V0-13.24 Practice Test

Whether you're a beginner or brushing up on skills, our 2V0-13.24 practice exam is your key to success. Our comprehensive question bank covers all key topics, ensuring you’re fully prepared.


Page 1 out of 18 Pages

An architect was requested to recommend a solution for migrating 5000 VMs from an existing vSphere environment to a new VMware Cloud Foundation infrastructure. Which feature or tool can be recommended by the architect to minimize downtime and automate the process?


A. VMware HCX


B. vSphere vMotion


C. VMware Converter


D. Cross vCenter vMotion





A.
  VMware HCX

Explanation:
When migrating 5000 virtual machines (VMs) from an existing vSphere environment to a new VMware Cloud Foundation (VCF) 5.2 infrastructure, the primary goals are to minimize downtime and automate the process as much as possible. VMware Cloud Foundation 5.2 is a full-stack hyper-converged infrastructure (HCI) solution that integrates vSphere, vSAN, NSX, and Aria Suite for a unified private cloud experience. Given the scale of the migration (5000 VMs) and the requirement to transition from an existing vSphere environment to a new VCF infrastructure, the architect must select a tool that supports large-scale migrations, minimizes downtime, and provides automation capabilities across potentially different environments or data centers.
Let’s evaluate each option in detail:
A. VMware HCX: VMware HCX (Hybrid Cloud Extension) is an application mobility platform designed specifically for large-scale workload migrations between vSphere environments, including migrations to VMware Cloud Foundation. HCX is included in VCF Enterprise Edition and provides advanced features such as zero-downtime live migration, bulk migration, and network extension. It automates the creation of hybrid interconnects between source and destination environments, enabling seamless VM mobility without requiring IP address changes (via Layer 2 network extension). HCX supports migrations from older vSphere versions (as early as vSphere 5.1) to the latest versions included in VCF 5.2, making it ideal for brownfield-to-greenfield transitions. For a migration of 5000 VMs, HCX’s ability to perform bulk migrations (hundreds of VMs simultaneously) and its high-availability features (e.g., redundant appliances) ensure minimal disruption and efficient automation. HCX also integrates with VCF’s SDDC Manager, aligning with the centralized management paradigm of VCF 5.2.
B. vSphere vMotion: vSphere vMotion enables live migration of running VMs from one ESXi host to another within the same vCenter Server instance with zero downtime. While this is an excellent tool for migrations within a single data center or vCenter environment, it is limited to hosts managed by the same vCenter Server. Migrating VMs to a new VCF infrastructure typically involves a separate vCenter instance (e.g., a new management domain in VCF), which vMotion alone cannot handle. For 5000 VMs, vMotion would require manual intervention for each VM and would not scale efficiently across different environments or data centers, making it unsuitable as the primary tool for this scenario.
C. VMware Converter: VMware Converter is a tool designed to convert physical machines or other virtual formats (e.g., Hyper-V) into VMware VMs. It is primarily used for physical-tovirtual (P2V) or virtual-to-virtual (V2V) conversions rather than migrating existing VMware VMs between vSphere environments. Converter involves downtime, as it requires powering off the source VM, cloning it, and then powering it on in the destination environment. For 5000 VMs, this process would be extremely time-consuming, lack automation for largescale migrations, and fail to meet the requirement of minimizing downtime, rendering it an impractical choice.
D. Cross vCenter vMotion: Cross vCenter vMotion extends vMotion’s capabilities to migrate VMs between different vCenter Server instances, even across data centers, with zero downtime. While this feature is powerful and could theoretically be used to move VMs to a new VCF environment, it requires both environments to be linked within the same Enhanced Linked Mode configuration and assumes compatible vSphere versions. For 5000 VMs, Cross vCenter vMotion lacks the bulk migration and automation capabilities offered by HCX, requiring significant manual effort to orchestrate the migration. Additionally, it does not provide network extension or the same level of integration with VCF’s architecture as HCX. 
Why VMware HCX is the Best Choice: VMware HCX stands out as the recommended solution for this scenario due to its ability to handle large-scale migrations (up to hundreds of VMs concurrently), minimize downtime via live migration, and automate the process through features like network extension and migration scheduling. HCX is explicitly highlighted in VCF 5.2 documentation as a key tool for workload migration, especially for importing existing vSphere environments into VCF (e.g., via the VCF Import Tool, which complements HCX). Its support for both live and scheduled migrations ensures flexibility, while its integration with VCF 5.2’s SDDC Manager streamlines management. For a migration of 5000 VMs, HCX’s scalability, automation, and minimal downtime capabilities make it the superior choice over the other options.

An architect is collaborating with a client to design a VMware Cloud Foundation (VCF) solution requiredfor a highly secure infrastructure project that must remain isolated from all other virtual infrastructures. The client has already acquired six high-density vSAN-ready nodes, and there is no budget to add additional nodes throughout the expected lifespan of this project. Assuming capacity is appropriately sized, which VCF architecture model and topology should the architect suggest?


A. Single Instance - Multiple Availability Zone Standard architecture model


B. Single Instance Consolidated architecture model


C. Single Instance - Single Availability Zone Standard architecture model


D. Multiple Instance - Single Availability Zone Standard architecture model





C.
  Single Instance - Single Availability Zone Standard architecture model

Explanation: VMware Cloud Foundation (VCF) 5.2 offers various architecture models (Consolidated, Standard) and topologies (Single/Multiple Instance, Single/Multiple Availability Zones) to meet different requirements. The client’s needs—high security, isolation, six vSAN-ready nodes, and no additional budget—guide the architect’s choice. Let’s evaluate each option:
Option A: Single Instance - Multiple Availability Zone Standard architecture model This model uses a single VCF instance with separate Management and VI Workload Domains across multiple availability zones (AZs) for resilience. It requires at least four nodes per AZ (minimum for vSAN HA), meaning six nodes are insufficient for two AZs (eight nodes minimum). It also increases complexity and doesn’t inherently enhance isolation from other infrastructures. This option is impractical given the node constraint.
Option B: Single Instance Consolidated architecture model The Consolidated model runs management and workload components on a single cluster (minimum four nodes, up to eight typically). With six nodes, this is feasible and capacityefficient, but it compromises isolation because management and user workloads share the same infrastructure. For a “highly secure” and “isolated” project, mixing workloads increases the attack surface and risks compliance, making this less suitable despite fitting the node count.
Option C: Single Instance - Single Availability Zone Standard architecture model This is the correct answer. The Standard model separates management (minimum four nodes) and VI Workload Domains (minimum three nodes, but often four for HA) within a single VCF instance and AZ. With six nodes, the architect can allocate four to the Management Domain and two to a VI Workload Domain (or adjust based on capacity). A single AZ fits the budget constraint (no extra nodes), and isolation is achieved by dedicating the VCF instance to this project, separate from other infrastructures. The high-density vSAN nodes support both domains, and security is enhanced by logical separation of management and workloads, aligning with VCF 5.2 best practices for secure deployments.
Option D: Multiple Instance - Single Availability Zone Standard architecture model Multiple VCF instances (e.g., one for management, one for workloads) in a single AZ require separate node pools, each with a minimum of four nodes for vSAN. Six nodes cannot support two instances (eight nodes minimum), making this option unfeasible given the budget and hardware constraints.
Conclusion: TheSingle Instance - Single Availability Zone Standard architecture model(Option C) is the best fit. It uses six nodes efficiently (e.g., four for Management, two for Workload), ensures isolation by dedicating the instance to the project, and meets security needs through logical separation, all within the budget limitation.

A customer has a database cluster running in a VCF cluster with the following characteristics:
40/60 Read/Write ratio.
High IOPS requirement.
No contention on an all-flash OSA vSAN cluster in a VI Workload Domain.
Which two vSAN configuration options should be configured for best performance? (Choose two.)


A. Flash Read Cache Reservation


B. RAID 1


C. Deduplication and Compression disabled


D. Deduplication and Compression enabled


E. RAID 5





B.
  RAID 1

C.
  Deduplication and Compression disabled

Explanation: The database cluster in a VCF 5.2 VI Workload Domain uses an all-flash vSAN Original Storage Architecture (OSA) cluster with a 40/60 read/write ratio, high IOPS needs, and no contention (implying sufficient resources). vSAN configuration impacts performance, especially for databases. Let’s evaluate:
Option A: Flash Read Cache ReservationIn all-flash vSAN OSA, the cache tier (flash) serves writes, not reads, which are handled by the capacity tier (also flash). ThevSAN Planning and Deployment Guidenotes that Flash Read Cache Reservation is deprecated for all-flash configurations, as reads don’t benefit from caching, making this irrelevant for performance here.
Option B: RAID 1RAID 1 (mirroring) replicates data across hosts, offering high performance and availability (FTT=1). For a 40/60 read/write workload with high IOPS, RAID 1 minimizes latency and maximizes throughput compared to erasure coding (e.g., RAID 5), as it avoids parity calculations. TheVCF 5.2 Architectural Guiderecommends RAID 1 for performance-critical workloads like databases, especially with no contention.
Option C: Deduplication and Compression disabledDisabling deduplication and compression avoids CPU overhead and latency from data processing, critical for high-IOPS workloads. ThevSAN Administration Guideadvises disabling these for performancesensitive applications (e.g., databases), as the 60% write ratio benefits from direct I/O over space efficiency, given no contention.
Option D: Deduplication and Compression enabledEnabling deduplication and compression reduces storage use but increases latency and CPU load, degrading performance for high-IOPS workloads. ThevSAN Planning and Deployment Guidenotes this trade-off, making it unsuitable here.
Option E: RAID 5RAID 5 (erasure coding) uses parity, reducing write performance due to calculations, which conflicts with the 60% write ratio and high IOPS needs. TheVCF 5.2 Architectural Guiderecommends RAID 5 for capacity optimization, not performance, favoring RAID 1 instead.
Conclusion:
B: RAID 1 ensures high performance for IOPS and write-heavy workloads.
C: Disabling deduplication and compression optimizes I/O performance.These align with vSAN best practices for all-flash database clusters in VCF 5.2.
References:
VMware Cloud Foundation 5.2 Architectural Guide(docs.vmware.com): vSAN Configuration for Performance.
vSAN Planning and Deployment Guide(docs.vmware.com): RAID Levels and All-Flash Settings.
vSAN Administration Guide(docs.vmware.com): Deduplication and Compression Impact.

An architect is designing a VMware Cloud Foundation (VCF)-based solution for a customer with the following requirement:
The solution must not have any single points of failure.
To meet this requirement, the architect has decided to incorporate physical NIC teaming for all vSphere host servers. When documenting this design decision, which consideration should the architect make?


A. Embedded NICs should be avoided for NIC teaming.


B. Only 10GbE NICs should be utilized for NIC teaming.


C. Each NIC team must comprise NICs from the same physical NIC card.


D. Each NIC team must comprise NICs from different physical NIC cards.





D.
  Each NIC team must comprise NICs from different physical NIC cards.

Explanation: In VMware Cloud Foundation 5.2, designing a solution with no single points of failure (SPOF) requires careful consideration of redundancy across all components, including networking. Physical NIC teaming on vSphere hosts is a common technique to ensure network availability by aggregating multiple networkinterface cards (NICs) to provide failover and load balancing. The architect’s decision to use NIC teaming aligns with this goal, but the specific consideration for implementation must maximize fault tolerance.
Requirement Analysis:
No single points of failure:The networking design must ensure that the failure of any single hardware component (e.g., a NIC, cable, switch, or NIC card) does not disrupt connectivity to the vSphere hosts.
Physical NIC teaming:This involves configuring multiple NICs into a team (typically via vSphere’s vSwitch or Distributed Switch) to provide redundancy and potentially increased bandwidth.
Option Analysis:
A. Embedded NICs should be avoided for NIC teaming:Embedded NICs (integrated on the server motherboard) are commonly used in VCF deployments and are fully supported for NIC teaming. While they may have limitations (e.g., fewer ports or lower speeds compared to add-on cards), there is no blanket requirement in VCF 5.2 or vSphere to avoid them for teaming. The VMware Cloud Foundation Design Guide and vSphere Networking documentation do not prohibit embedded NICs; instead, they emphasize redundancy and performance. This consideration is not a must and does not directly address SPOF, so it’s incorrect.
B. Only 10GbE NICs should be utilized for NIC teaming:While 10GbE NICs are recommended in VCF 5.2 for performance (especially for vSAN and NSX traffic), there is no strict requirement thatonly10GbE NICs be used for teaming. VCF supports 1GbE or higher, depending on workload needs, as long as redundancy is maintained. The requirement here is about eliminating SPOF, not mandating a specific NIC speed. For example, teaming two 1GbE NICs could still provide failover. This option is too restrictive and not directly tied to the SPOF concern, making it incorrect.
C. Each NIC team must comprise NICs from the same physical NIC card:If a NIC team consists of NICs from the same physical NIC card (e.g., a dual-port NIC), the failure of that single card (e.g., hardware failure or driver issue) would disable all NICs in the team, creating a single point of failure. This defeats the purpose of teaming for redundancy. VMware best practices, as outlined in the vSphere Networking Guide and VCF Design Guide, recommend distributing NICs across different physical cards or sources (e.g., one from an embedded NIC and one from an add-on card) to avoid this risk. This option increases SPOF risk and is incorrect.
D. Each NIC team must comprise NICs from different physical NIC cards:This is the optimal design consideration for eliminating SPOF. By ensuring that each NIC team includes NICs from different physical NIC cards (e.g., one from an embedded NIC and one from a PCIe NIC card), the failure of any single NIC card does not disrupt connectivity, as the other NIC (on a separate card) remains operational. This aligns with VMware’s highavailability best practices for vSphere and VCF, where physical separation of NICs enhances fault tolerance. The VCF 5.2 Design Guide specifically advises using multiple NICs from different hardware sources for redundancy in management, vSAN, and VM traffic. This option directly addresses the requirement and is correct.
Conclusion:The architect should document thateach NIC team must comprise NICs from different physical NICcards (D)to ensure no single point of failure. This design maximizes network redundancy by protecting against the failure of any single NIC card, aligning with VCF’s high-availability principles.

A customer is implementing a new VMware Cloud Foundation (VCF) instance and has a requirement to deploy Kubernetes-based applications. The customer has no budget for additional licensing. Which VCF feature must be implemented to satisfy the requirement?


A. Tanzu Mission Control


B. VCF Edge


C. Aria Automation


D. IaaS control plane





D.
  IaaS control plane

Explanation:
The customer requires Kubernetes-based application deployment within a new VCF 5.2 instance without additional licensing costs. VCF includes foundational components and optional features, some requiring separate licenses. Let’s evaluate each option:
Option A: Tanzu Mission ControlTanzu Mission Control (TMC) is a centralized management platform for Kubernetes clusters across environments. It’s a SaaS offering requiring a separate subscription, not included in the base VCF license. The VCF 5.2 Architectural Guideexcludes TMC from standard VCF features, making it incompatible with the no-budget constraint.
Option B: VCF EdgeVCF Edge refers to edge computing deployments (e.g., remote sites) using lightweight VCF instances. It’s not a Kubernetes-specific feature and doesn’t inherently provide Kubernetes capabilities without additional configuration or licensing (e.g., Tanzu). The VCF 5.2 Administration Guidepositions VCF Edge as an architecture, not a Kubernetes solution.
Option C: Aria AutomationAria Automation (formerly vRealize Automation) provides cloud management and orchestration, including some Kubernetes integration via Tanzu Service Mesh or custom workflows. However, it’s an optional component in VCF, often requiring additional licensing beyond the base VCF bundle, per theVCF 5.2 Licensing Guide. It’s not mandatory for basic Kubernetes and violates the budget restriction.
Option D: IaaS control planeIn VCF 5.2, the IaaS control plane includes VMware Cloud Director or the native vSphere with Tanzu capability (via NSX and vSphere 7.x). vSphere with Tanzu, enabled through the Workload Management feature, provides a Supervisor Cluster for Kubernetes without additional licensing beyond VCF’s core components (vSphere, vSAN, NSX). TheVCF 5.2 Architectural Guideconfirms that vSphere with Tanzu is included in VCF editions supporting NSX, allowing Kubernetes-based application deployment (e.g., Tanzu Kubernetes Grid clusters) at no extra cost.
Conclusion: TheIaaS control plane (D), leveraging vSphere with Tanzu, meets the requirement for Kubernetes deployment within VCF 5.2’s existing licensing, satisfying the no-budget constraint.
References:

  • VMware Cloud Foundation 5.2 Architectural Guide(docs.vmware.com): IaaS Control Plane and vSphere with Tanzu.
  • VMware Cloud Foundation 5.2 Administration Guide(docs.vmware.com): Workload Management Features.
  • VMware Cloud Foundation 5.2 Licensing Guide(docs.vmware.com): Included Components.


Page 1 out of 18 Pages